Comparison of masking level difference in patients with multiple sclerosis and healthy control group

Abstract

Background and Aim: Multiple sclerosis (MS) is a neurological disorder that involves central nervous system. Studies have showed that multiple sclerosis affects behavioral central auditory tests, such as masking release or masking level difference (MLD). The purpose of this study is to compare the masking level difference between multiple sclerosis patients and normal subjects.
Methods: This cross sectional and non-interventional study was conducted on 32 multiple sclerosis patients aged between 20-50 years and 32 controls matched for age and gender in Faculty of Rehabilitation, Tehran University of Medical Sciences. masking level difference test was performed on each subject.
Results: The mean masking level difference in the two groups was significantly different (p<0.01) however, gender did not prove to play a role in this difference.
Conclusion: As part of the multiple sclerosis diagnosis panel, masking level difference test is an efficient modality for evaluation of hearing impairment and monitoring of rehabilitation progress.

1. Brassat D. Pathophysiology of multiple sclerosis. Presse Med. 2010;39(3):341-8.
2. Grénman R. Involvement of the audiovestibular system in multiple sclerosis. An otoneurologic and audiologic study. Acta Otolaryngol suppl. 1985;420:1-95.
3. Doris-Eva B. Measures of binaural interaction. In: Chermak GD, Musiek FE. Central auditory processing disorders. San Diego: Singular publishing group; 2006. p. 257-86.
4. Alekseeva NS, Kirichenko IM, Zavalishin IA, Peresedova AV, Fedin PA, Klochkov AM. The role of the otoneurological method in early diagnosis of multiple sclerosis. Vestn Otorinolaringol. 2006;(6):18-22. Russian.
5. Bellis TJ. Assessment and management of central auditory processing disorder, in the educational setting: from science to practice. 2nd ed. San Diego: Singular publishing group; 2002.
6. Matathias O, Sohmer H, Biton V. Central auditory tests and auditory nerve-brainstem evoked responses in multiple sclerosis. Acta Otolaryngol. 1985;99(3-4):369-76.
7. Buschermöhle M, Verhey JL, Feudel U, Freund JA. The role of the auditory periphery in comodulation detection difference and comodulation masking release. Biol Cybern. 2007;97(5-6):397-411.
8. Wilson RH, Moncrieff DW, Townsend EA, Pillion AL. Development of a 500-Hz masking-level difference protocol for clinic use. J Am Acad Audiol. 2003;14(1):1-8.
9. Olsen WO, Noffsinger D. Masking level differences for cochlear and brain stem lesions. Ann Otol Rhinol Laryngol. 1976;85(6 PT. 1):820-5.
10. Güven AG, Mutlu M. The use of masking level differences in evaluating central auditory processing: the norms for the normal hearing subjects. Kulak Burun Bogaz Ihtis Derg. 2003;10(3):93-7. Turkish.
11. Hendler T, Squires NK, Emmerich DS. Psychophysical measures of central auditory dysfunction in multiple sclerosis: neurophysiological and neuroanatomical correlates. Ear Hear. 1990;11(6):403-16 .
12. Hannley M, Jerger JF, Rivera VM. Relationships among auditory brain stem responses, masking level differences and the acoustic reflex in multiple sclerosis. Audiology. 1983;22(1):20-33.
13. Musiek FE, Gollegly KM, Kibbe KS, Reeves AG. Electrophysiologic and behavioral auditory findings in multiple sclerosis. Am J Otol. 1989;10(5):343-50
14. Jiang D, McAlpine D, Palmer AR. Detectability index measures of binaural masking level difference across populations of inferior colliculus neurons. J Neurosci. 1997;17(23):9331-9.
15. Palmer AR, Shackleton TM. The physiological basis of the binaural masking level difference. Acta Acustica united with Acustica. 2002;88(3):312-9.
IssueVol 21 No 1 (2012) QRcode
SectionResearch Article(s)
Keywords
Multiple sclerosis behavioral central auditory tests masking level difference masking release

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Mohamadkhani G, Younessi F, Sedaie M, Majidi H, Faghihzadeh S. Comparison of masking level difference in patients with multiple sclerosis and healthy control group. Aud Vestib Res. 2017;21(1):1-7.